- Nine-bus, Three-Machines, Three-Load, P. M. Anderson Test System.
- P.M. Anderson 9bus Test Case DIgSILENT PowerFactory
- IEEE 14 bus
- IEEE 14bus DIgSILENT PowerFactory
- IEEE 30 bus
- IEEE 39 bus
- IEEE 57 bus
- IEEE 118 bus
- IEEE 300 bus
- Kumamoto Distribution System, 14 nodes
- FGL's 3 bus Test System
- FGL's 3 bus Test System with TAP's
- FGL's 5 bus Test System
- FGL's 5 bus Test System considering reactive power limits
- FGL's 5 bus Test System considering capacitve susceptance
- FGL's 5 bus Test System considering reactive power compensation
- FGL's 6 bus Test System
- FGL's 8 bus Test System with TAP's
- Stagg and El-Adiad Test System
- José Marti's Test System
- FGL's 5 bus Test System: Radial Topology
- FGL's 5 bus Test System: Mesh Topology
Power System Test Cases
Introduction
This page was created and maintained by Dr. Francisco M. Gonzalez-Longatt in order to provide World Wide Web access to power system data (test cases).
You can send submissions, questions and requests to fglongatt@fglongatt.org.
To use the archive, select the test case that interests you, then select the appropriate parts of it. If you have selected a text file, its contents will appear on your browser. At this point, use the "File Save As" option to download it. Other file types will invite you to save them when you select them
Disclaimer and Content Policy
This archive is operated voluntarily as a public service. There is not cost associated with this documents, everything is free of charge.
No guarantees of any kind regarding the correctness, currency, functionality, usability or any other attribute of the archived material can be made. Use at your own risk.
Material in the archive is intended for purposes of research and education, not for commercial gain.
Material that is known to be copyrighted or proprietary will not be accepted without specific permission from the owner.
Copyrighted or proprietary material that inadvertently appears in the archive will be removed as soon as its status is called to the attention of the archive maintainer.
Submissions Submissions to the archive are encouraged.
Submissions are screened before they are placed in the archive.
People sending submissions will be credited! To submit, send email with your submission attached to fglongatt@fglongatt.org. Please put Archive Submission on your subject line.
- All CASES!!! Read it
- 3-Node, 1 Wind Farm, 2 AC Systems
- 5-Node, 2 Wind Farms, 3 AC Systems
- 7-Node, 3 Wind Farms, 2 AC Systems
- 11-Node, 5 Wind Farms, 3 AC Systems
- 19-Node, 9 Wind Farms, 5 AC Systems
Power Flow Test Cases
Dynamic Test Cases
High Voltage DC Test Cases
Disclaimer and Content Policy
This archive is operated voluntarily as a public service. No guarantees of any kind regarding the correctness, currency, functionality, usability or any other attribute of the archived material can be made. Use at your own risk.
Material in the archive is intended for purposes of research and education, not for commercial gain. Material that is known to be copyrighted or proprietary will not be accepted without specific permission from the owner. Copyrighted or proprietary material that inadvertently appears in the archive will be removed as soon as its status is called to the attention of the archive maintainer.